These measures are eligible for rebates through Energy Efficiency Alberta’s Business, Non-Profit, and Institutional Energy Savings Program. Any product purchased by an eligible organization on or after March 24, 2017 (as per invoice dates) is eligible for a rebate once the program launches in May. Once you’ve installed one or more of these eligible measures, you can return to efficiencyalberta.ca after program launch and apply for the rebate. Once approved, you’ll receive a cheque that will help cover the cost of the equipment.

Lighting | LED Interior Measures

Surface and suspended linear fixtures

Equal to or greater than 7,500 lumens

On DLC Qualified Products List:

  • Category: Indoor – Linear Ambient Luminaire
  • Primary use: Direct linear ambient luminaires or linear ambient luminaires with indirect component
  • Equal to or greater than 7,500 lumens

Troffer fixtures and retrofit kits

2×2 troffer

On DLC Qualified Products List:

  • Category: Indoor Luminaire – Troffer
  • Primary Use: 2×2 Luminaires for Ambient Lighting of interior commercial spaces

Troffer fixtures and retrofit kits

1×4 troffer

On DLC Qualified Products List:

  • Category: Indoor Luminaire – Troffer
  • Primary Use: 1×4 luminaires for ambient lighting of interior commercial spaces

Troffer fixtures and retrofit kits

2×4 troffer

On DLC Qualified Products List:

  • Category: Indoor Luminaire – Troffer
  • Primary Use: 2×4 luminaires for ambient lighting of interior commercial spaces

2′ and 4′ LED replacement lamps (tubes)

2′ linear replacement lamp

On DLC Qualified Products List:

– Category as Replacement Lamps (UL Type A only). Dual Mode Internal Driver (hybrids of UL Type A and Type B) are not eligible for this incentive.

– Only LED T8 lamps designed to replace traditional fluorescent T8 lamps and engineered to operate on existing instant start, programmed start electronic T8 ballasts are eligible. It is the Applicant’s responsibility to confirm that the existing ballasts are compatible for use with the new LED tube lamps.

2′ and 4′ LED replacement lamps (tubes)

4′ linear replacement lamp

On DLC Qualified Products List:

– Category as Replacement Lamps (UL Type A only). Dual Mode Internal Driver (hybrids of UL Type A and Type B) are not eligible for this incentive.

– Only LED T8 lamps designed to replace traditional fluorescent T8 lamps and engineered to operate on existing instant start, programmed start electronic T8 ballasts are eligible. It is the Applicant’s responsibility to confirm that the existing ballasts are compatible for use with the new LED tube lamps.

Low-bay / medium-bay/ high-bay fixtures and retrofit kits

Less than or equal to 10,000 lumens

On DLC Qualified Products List:

  • Category: Indoor Luminaires – High Bay
  • Primary use: High bay luminaires for commercial and industrial buildings or low /high bay aisle luminaires
  • Less than or equal to 10,000 lumens

Low-bay / medium-bay/ high-bay fixtures and retrofit kits

Equal to or greater than 10,000 lumens and less than 15,000 lumens

On DLC Qualified Products List:

  • Category: Indoor Luminaires – High Bay – Primary use: High bay luminaires for commercial and industrial buildings or low /high bay aisle luminaires
  • Equal to or greater than 10,000 lumens and less than 15,000 lumens

Low-bay / medium-bay/ high-bay fixtures and retrofit kits

Equal to or greater than 15,000 lumens and less than 20,000 lumens

On DLC Qualified Products List:

  • Category: Indoor Luminaires – High Bay
  • Primary use: High bay luminaires for commercial and industrial buildings or low /high bay aisle luminaires
  • Equal to or greater than 15,000 lumens and less than 20,000 lumens

Low-bay / medium-bay/ high-bay fixtures and retrofit kits

Equal to or greater than 20,000 lumens

On DLC Qualified Products List:

  • Category: Indoor Luminaires – High Bay
  • Primary use: High bay luminaires for commercial and industrial buildings or low /high bay aisle luminaires
  • Equal to or greater than 20,000 lumens

LED lamp

Screw-based or pin-based replacement – less than 5 watts and equal to or greater than 250 lumens

On ENERGY STAR® list of Certified Light Bulbs:

  • Eligible types: A19, A21, BR30, BR40, Decorative-Other, MR16, PAR16, PAR20, PAR30, PAR30L, PAR38 and R20
  • 5 watts and equal to or greater than 250 lumens

LED lamp

Screw-based or pin-based replacement – less than 8 watts and equal to or greater than 400 lumens

On ENERGY STAR® list of Certified Light Bulbs:

  • Eligible types: A19, A21, BR30, BR40, Decorative-Other, MR16, PAR16, PAR20, PAR30, PAR30L, PAR38 and R20
  • 8 watts and equal to or greater than 400 lumens

Downlight fixtures & retrofit kits

Equal to or greater than 400 lumens and less than 600 lumens

On ENERGY STAR® list of Certified Light Fixtures:

  • Eligible Fixture Type categories “Downlight Recessed or Downlight Solid State Retrofit or Downlight Pendant or Downlight Surface Mount”
  • Equal to or greater than 400 lumens and less than 600 lumens

Downlight fixtures & retrofit kits

Equal to or greater than 600 lumen and less than 800 lumens

On ENERGY STAR® list of Certified Light Fixtures:

  • Eligible Fixture Type categories “Downlight Recessed or Downlight Solid State Retrofit or Downlight Pendant or Downlight Surface Mount”
  • Equal to or greater than 600 lumens and less than 800 lumens

Downlight fixtures & retrofit kits

Greater than 800 lumens

On ENERGY STAR® list of Certified Light Fixtures:

  • Eligible Fixture Type categories “Downlight Recessed or Downlight Solid State Retrofit or Downlight Pendant or Downlight Surface Mount”
  • Equal to or greater than 800 lumens

LED accent/track lighting fixtures

On ENERGY STAR® Hard-wired fixture:

  • Indoor (accent/track, ceiling mount, omni-directional wall)

Refrigerated, freezer and display case

On DLC list of qualified fixtures (Horizontal and Vertical “Refrigerated Case Lighting” categories)

Freezer case

On DLC list of qualified fixtures (Horizontal and Vertical “Refrigerated Case Lighting” categories)

Display case

On DLC list of qualified fixtures (Horizontal and Vertical “Refrigerated Case Lighting” categories)

Surface and suspended linear fixtures

less than or equal to 3,000 lumens

On DLC Qualified Products List:

  • Category: Indoor – Linear Ambient Luminaire
  • Primary use: Direct linear ambient luminaires or linear ambient luminaires with indirect component
  • Less than or equal to 3,000 lumens

Surface and suspended linear fixtures

Equal to or greater than 3,000 lumens and less than 4,500 lumens

On DLC Qualified Products List:

  • Category: Indoor – Linear Ambient Luminaire
  • Primary use: Direct linear ambient luminaires or linear ambient luminaires with indirect component
  • Equal to or greater than 3,000 lumens and less than 4,500 lumens

Surface and suspended linear fixtures

Equal to or greater than 4,500 lumens and less than 6,000 lumens

On DLC Qualified Products List:

  • Category: Indoor – Linear Ambient Luminaire
  • Primary use: Direct linear ambient luminaires or linear ambient luminaires with indirect component
  • Equal to or greater than 4,500 lumens and less than 6,000 lumens

Surface and suspended linear fixtures

Equal to or greater than 6,000 lumens and less than 7,500 lumens

On DLC Qualified Products List:

  • Category: Indoor – Linear Ambient Luminaire
  • Primary use: Direct linear ambient luminaires or linear ambient luminaires with indirect component
  • Equal to or greater than 6,000 lumens and less than 7,500 lumens

Return to top

Lighting | LED Exterior Measures

LED pole/arm mounted: parking / roadway / bollard and flood light retrofit fixtures

Less than or equal to 5,000 lumens

On DLC Qualified Products List:

  • Category: Outdoor Luminaires – Low, Medium, High Output
  • Primary use: Outdoor pole/ arm-mounted area and roadway luminaires
  • Includes: Pole-mounted area fixtures and retrofit kits; Decorative area or post-top area fixtures and retrofit kits; Parking garage or canopy fixtures and retrofit kits; Wall-mounted fixtures (including wall packs) and retrofit kits; Bollard fixtures; Outdoor flood light fixtures
  • Less than or equal to 5,000 lumens

LED pole or arm mounted: parking, roadway, bollard and flood-light retrofit fixtures

Equal to or greater than 5,000 lumens and less than 10,000 lumens

On DLC Qualified Products List:

  • Category: Outdoor Luminaires – Low, Medium, High Output
  • Primary use: Outdoor pole/ arm-mounted area and roadway luminaires
  • Includes: Pole-mounted area fixtures and retrofit kits; Decorative area or post-top area fixtures and retrofit kits; Parking garage or canopy fixtures and retrofit kits; Wall-mounted fixtures (including wall packs) and retrofit kits; Bollard fixtures; Outdoor flood light fixtures
  • Equal to or greater than 5,000 lumens and less than 10,000 lumens

LED pole or arm mounted: parking, roadway, bollard and flood-light retrofit fixtures

Equal to or greater than 10,000 lumens and less than 15,000 lumens

On DLC Qualified Products List:

  • Category: Outdoor Luminaires – Low, Medium, High Output
  • Primary use: Outdoor pole/ arm-mounted area and roadway luminaires
  • Includes: Pole-mounted area fixtures and retrofit kits; Decorative area or post-top area fixtures and retrofit kits; Parking garage or canopy fixtures and retrofit kits; Wall-mounted fixtures (including wall packs) and retrofit kits; Bollard fixtures; Outdoor flood light fixtures
  • Equal to or greater than 10,000 lumens and less than 15,000 lumens

LED pole or arm mounted: parking, roadway, bollard and flood-light retrofit fixtures

Equal to or  greater than 15,000 lumens

On DLC Qualified Products List:

  • Category: Outdoor Luminaires – Low, Medium, High Output
  • Primary use: Outdoor pole/ arm-mounted area and roadway luminaires
  • Includes: Pole-mounted area fixtures and retrofit kits; Decorative area or post-top area fixtures and retrofit kits; Parking garage or canopy fixtures and retrofit kits; Wall-mounted fixtures (including wall packs) and retrofit kits; Bollard fixtures; Outdoor flood light fixtures
  • Equal to or greater than 15,000 lumens

Return to top

Lighting | Interior Control Measures

Interior daylight controls

Fixture mounted dual occupancy and daylight controls – integrated or fixture mounted

Sensors with “manual on override” are not eligible (i.e. automatic off cannot be disabled)

Interior occupancy controls

Ceiling or remote mounted sensor – minimum 150 watts controlled

Sensors with “manual on override” are not eligible (i.e. automatic off cannot be disabled)

Interior occupancy controls

Wall/switch mounted sensor – minimum 60 watts controlled

Sensors with “manual on override” are not eligible (i.e. automatic off cannot be disabled)

Interior occupancy controls

fixture mounted sensor – minimum 30 watts controlled

Sensors with “manual on override” are not eligible (i.e. automatic off cannot be disabled)

Interior occupancy controls

refrigerated case sensor – minimum 3 doors per sensor

Sensors with “manual on override” are not eligible (i.e. automatic off cannot be disabled)

Interior occupancy controls

freezer case sensor – minimum 3 doors per sensor

Sensors with “manual on override” are not eligible (i.e. automatic off cannot be disabled)

Interior daylight controls

ceiling or wall remote mounted – minimum 150 watts controlled

Sensors with “manual on override” are not eligible (i.e. automatic off cannot be disabled)

Interior daylight controls

Switch or fixture mounted – minimum 30 watts controlled

Sensors with “manual on override” are not eligible (i.e. automatic off cannot be disabled)

Return to top

Lighting | Exterior Control Measures

Exterior occupancy sensors

Minimum 45 watts controlled

Sensors with “manual on override” are not eligible (i.e. automatic off cannot be disabled)

Return to top

Heating, Ventilation and Air Conditioning (HVAC) Measures

High-Efficiency Furnace

AFUE greater than 96% Less than 300 MMBtu/hr.

Condensing Boiler – Less than 300 MBTU/hr

AFUE greater than 90% Less than 300 MMBtu/hr., Hot Water

Condensing Boiler – Greater than 300 MBTU/hr but less than 2500 MBTU / hr

Thermal efficiency greater than 90%, greater than 300 and Less than 2500 MMBtu/hr. Hot Water

Condensing Boiler – Greater than 2500 MBTU/hr

Thermal efficiency greater than 90%, greater than 2,500 MMBtu/hr. Hot Water

Near-Condensing Boiler

AFUE greater than 85%, Less than 300 MMBtu/hr. Hot Water

Near-Condensing Boiler

Thermal efficiency greater than 85%, greater than 300 MMBtu/hr. Hot Water

Return to top

Water Heating Measures

Condensing Storage Water Heater

Energy Factor greater than 80%, less than or equal to 75 kBTU/h

Condensing Storage Water Heater

Thermal efficiency greater than 90%, greater than 75 kBTU/h

Condensing Tankless Water Heater

Energy Factor greater than or equal 90%, greater than 75 kBTU/h